Agilent / HP / Keysight 8563E
8563E Portable Spectrum Analyzer, 9 kHz to 26.5 GHz
Description
The Agilent/HP 8563E is a spectrum analyzer which has a standard frequency range of 9 kHz to 26.5 GHz, with optional low-end frequency coverage to 30 Hz.
The 8563E offers the measurement capabilities and performance traditionally found only in larger, more expensive benchtop analyzers.
The 8563E combines outstanding phase noise, sensitivity, 1 Hz resolution bandwidths, synthesized tuning and wide dynamic range in a MIL-rugged package built to withstand harsh environmental conditions.
The 8563E offers a complete solution for adjacent-channel power (ACP) testing of burst carrier signals using digital modulation, and the ability to measure occupied bandwidth percentage.
The 8563E provides a low cost solution when used with Agilent 11970 series harmonic mixers or Agilent 11974 series pre-selected mixers for millimeter applications that don’t require full microwave coverage.
Key Points
Fast digital resolution bandwidths of 1, 3, 10, 30 and 100 Hz
Adjacent channel power, channel power, carrier power, occupied
bandwidth percentage and time-gated measurements standard
MIL-T-28800 rugged
Measurement personalities for digital radio and phase noise measurements
Portable, MIL-PRF-28800, Class 3 rugged
Easily transfer screen image or trace data to PC with BenchLink software E4444A BenchLink software
Specifications
Frequency range:
Internal mixing:30 Hz to 26.5 GHz
External mixing:18 GHz to 325 GHz
Sweep time:
Range:
Span = 0 Hz:50 µs to 6000 s
Span ±100 Hz:
RBW >=300 Hz: 50 ms to 2000 s
RBW <=100 Hz: 50 ms to 100 ks
Resolution bandwidth:
Range (–3 dB) :1 Hz to 1 MHz in a 1, 3, 10 sequence and 2 MHz (3 MHz at –6 dB)
Video bandwidth: 1 Hz to 3 MHz in a 1, 3, 10 sequence
Maximum safe input level:
Average continuous power: +30 dBm (1 W, input attn =10 dB)
Peak pulse power(=10 µs pulse width,<1% duty cycle):+50 dBm (100 W,input attn =30 dB)
Displayed average noise level (DANL)(0 dB attenuation, 1 Hz resolution bandwidth):
30 Hz:<=90 dBm
1 kHz:<=105 dBm
10 kHz:<=120 dBm
100 kHz:<=120 dBm
1 MHz to 10 MHz:<=140 dBm
10 MHz to 2.9 GHz:<=151 dBm
2.9 GHz to 6.46 GHz:<=148 dBm
6.46 GHz to 13.2 GHz:<= 145 dBm
13.2 GHz to 22.0 GHz:<=140 dBm
22.0 GHz to 26.8 GHz:<= 139 dBm
Dynamic range:
Compression to noise:
10 MHz to 2.9 GHz:>144 dB
2.9 GHz to 6.46 GHz: >148 dB
6.46 GHz to 13.2 GHz:>142 dB
13.2 GHz to 22.0 GHz:>137 dB
22.0 GHz to 26.8 GHz: >136 dB
Harmonic:
20 MHz to 1.45 GHz:>94 dB
1.45 GHz to 2 GHz: >111.5 dB
2 GHz to 3.25 GHz : >119 dB
3.25 GHz to 6.6 GHz:>117.5 dB
6.6 GHz to 11 GHz :>115 dB
11 GHz to 13.4 GHz: >114.5 dB
Intermodulation:
10 MHz to 2.9 GHz:>107 dB
2.9 GHz to 6.46 GHz:>108.5 dB
6.46 GHz to 13.2 GHz: >101.5 dB
13.2 GHz to 22.0 GHz:>98 dB
22.0 GHz to 26.8 GHz:>97.5 dB
Reference level range ;Log, adjustable in 0.1 dB steps:
30 Hz to 31.15 GHz: –120 to +30 dBm
31.15 GHz to 50 GHz :–115 to +30 dBm
Environmental specifications:
Calibration interval:1 year
Warm-up time: 5-minutes in ambient conditions
Temperature:–10 °C to +55 °C (operating); –51 °C to +71 °C (not operating
Maximum power dissipation:180 W
Dimensions (w/o handle, cover): 337 mm W x 187 mm H x 461 mm D
Weight (nominal):20 kg (44 lbs)
##Power requirements:
115 VAC operation: 90 to 140 V rms, 3.2 A rms max, 47 to 440 Hz
230 VAC operation: 180 to 250 V rms, 1.8 A rms max, 47 to 66 Hz