Anritsu MT8802A
Radio Communication Analyzer CDMA, 300 kHz to 3 GHz
Description
The MT8802A was designed to support the test needs of the manufacturing, R&D and maintenance markets. All major radio communication systems in the world, including IS-95, GSM/DCS1800/PCS1900, IS-136A, AMPS/NAMPS, PDC, and PHS, can be evaluated using just one MT8802A Radio Communication Analyzer, covering the 300 kHz to 3 GHz frequency band in one hardware platform, and the dedicated measurement software options. This tester supports Service Options 1, 2 and 9 for IS-95 and J-Std-008 as well as call processing and sensitivity testing using the loopback method for GSM/DCS1800/PCS1900 and IS-136A. The call processing function, transmission/reception measurement functions, analog measurement function, and thermocouple power meter are provided as standard features. And when the spectrum analyzer function is added as an option, the MT8802A becomes a general-purpose spectrum analyzer that covers the frequency range of 10MHz to 3GHz.
FM radio transmission/reception tests are simplified by using the analog measurement function, and the optional spectrum analyzer function covering 10 MHz to 3 GHz is very useful for maintaining and measuring spurious near carrier on production lines. GPIB and RS-232C interfaces are standard, so MT8802A can be incorporated easily into automated production lines or on-site automated testing systems.
The time required for testing equipment on production lines is greatly reduced using the high-speed adjacent channel power and occupied bandwidth measurement functions based on Anritsu's proprietary measurement algorithm and DSP (Digital Signal Processing).
Furthermore, major transmission test items such as transmission frequency, modulation accuracy (phase error), transmission power, rise/fall characteristics of burst wave, adjacent channel power, etc. can be measured.
Key Points
Integrated tester for measurement of IS-95 cellular phones
Multiformat testing capability for IS-136A AMPS/NAMPS, GSM, PDC and PHS
Eight test instruments integrated into a single package
Fast, accurate measurements for manufacturing, R&D and maintenance
Specifications
General:
Frequency range: 300 kHz to 3 GHz
Maximum input level:+40 dBm (10 W); AUX: +20 dBm (100 mW)
Main input/output connector:Connector: N type; Impedance: 50 ohm; VSWR: <=1.2 (<=2.2 GHz); <=1.3 (>2.2 GHz)
Auxiliary input/output connector: TNC type
Reference oscillator:
Frequency: 10 MHz
Starting characteristics: <=5 x 10–8/day (After 10 minutes of warm-up, referred to frequency after 24-hour warm-up)
Aging rate: <=2 x 10–8/day, <=1 x 10–7/year, Referred to frequency after 24-hour warm-up
Temperature characteristics: <=5 x 10–8 (0° to 50°C, referred to frequency at 25°C)
External reference input: 10 or 13 MHz (±1 ppm), 2 to 5 Vp-p
Signal generator:
Frequency:10 MHz to 3 GHz, Resolution: 1 Hz, Accuracy: Reference oscillator accuracy ±100 mHz
Output level:
Level range:(no modulation or analog modulation): –13 to –133 dBm (Main), +7 to –133 dBm (AUX)
Level accuracy:
±1 dB (10 MHz to 2.2 GHz, >=–123 dBm, 18° to 28°C), ±3 dB (10 MHz to 2.2 GHz, >=–133 dBm),
±2 dB (>2.2 GHz,>=–123 dBm, 18° to 28°C), ±4 dB (>2.2 GHz, level: >=–133 dBm)
Others:
Display:Color TFT-LCD, Size : 7.8 inches; Number of dots : 640 x 480 dots
Dimensions and mass: 426 (W) x 221.5 (H) x 451 (D) mm, ²27 kg
Power: 100 to 120/200 to 240 Vac (automatic voltage switch system), 47.5 to 63 Hz, ²300 VA
Operating temperature: 0° to +50°C