Anritsu MD1620C
Signaling Tester
Description
This signaling tester has all the functions needed for operation tests and function tests of CS/PS for PHSs.
It has an air interface according to RCR STD-28 and can be used as a PS/CS simulator.
Control sequences, such as standby, registration, origination, termination, CH handover, disconnection by CS, and disconnection by PS can be tested.
This unit is a good choice for connection tests at the last stage of production lines of PS/CS and for function tests at the development stage.
Key Points
Built-in CODEC, and communication tests between the simulator and a CS/PS are possible using a hand-et supplied as a standard accessory
Parameters and optional sequences for tests can be freely defined
Layer 3 sequences can be freely defined and layer 3 semi-normal sequence tests are possible
Defined sequences and parameters can be stored on a 3.5 inch floppy disk
Easy to use operation system by windows and menu selection method
Specifications
Frequency range: 1895.15 to 1917.95MHz
Frequency setting interval: 300KHz steps
Number of carriers: 2carriers
Transmission level range: 13 to 83dBuV per carrier
Transmission level accuracy: ±2dB (24 to 83dBuV) at 25° ±5°C
Rx
Frequency range: 1895.15 to 1917.95MHz
Frequency setting interval: 300KHz steps
Number of carriers: 1carrier
Receiving level range: 77 to 149dBuV
Receiving error rate: BER less than 1 x 10-8 at 77dBuV