Agilent / HP / Keysight 8664A
8664A High-Performance Signal Generator, 3 GHz
- 90 Day Warranty Included
- 12 Month Warranty Available
- Save 80% - 90% from New
- Calibration Available
- Questions? Call 888-505-8378
Description
The Agilent 8664A signal generator is suited for basic receiver testing up to 3.0 GHz. With Option 004 (low-noise enhancement), it can be used for out-of-channel receiver testing or as a clock source where having the lowest phase jitter is important. Radar testing can be done by adding Option 008 (pulse modulation) .
Pulse width and delay can be internally adjusted between 50 ns and 999 ns, eliminating the need for an external pulse generator. Standard FM rates of up to 2 MHz and deviations to 10 MHz are suitable for many applications such as high-speed digital communications.
Key Points
<-140 dBc/Hz typical SSB phase noise at 20 kHz offset at 1 GHz with Option 004
<-100 dBc nonharmonic spurious to 2 GHz reduces error when testing spurious immunity of receivers
AM, FM, and optional pulse modulation
0.01 Hz frequency resolution
Onsite repair and calibration
Specifications
Frequency:
Range:0.1 to 3000 MHz
Resolution: 0.01 Hz
Switching speed (typical):< 50 ms (within 0.33 ppm)
Spectral purity:
Harmonics:< –30 dBc, output = +10 dBm
SSB phase noise (dBc/Hz):
4120 to 6000 Mhz:–105
3000 to 4120 Mhz:–105
2060 to 3000 Mhz:–111
1030 to 2060 Mhz:–111
515 to 1030 Mhz:–117
257.5 to 515 Mhz:–122
187.5 to 257.5 Mhz:–128
0.1 to 187.5 Mhz:–117
Nonharmonics:
< –100 dBc, > 10 kHz offset,187.5 to 2060 MHz
< –90 dBc, > 10 kHz offset,2060 to 6000 MHz, 0.1 to 187.5 MHz
Output level:
Range:+13 to -139.9 dBm
Resolution: 0.01 Hz
Absolute accuracy:
±1 dB, output >=–119.9 dBm, 1 - 1000 MHz
±1.5 dB, output >= –119.9 dBm, 1000 to 3000 MHz
±2 dB, output >= –119.9 dBm, 3000 to 6000 1, < 1 MHz
±3 dB, output >= –129.9 dBm
Frequency sweep:
Digital sweep: Digitally stepped sweep over entire frequency range. Linear/log selection. 0.5 to 1000 sec sweeps.
Markers/Z axis output: Three markers available /Z axis output nominally +5 V/X axis output nominally 0 to 10 V.
Phase continuous sweep: 40 MHz of span available at maximum carrier frequency. Twenty ms to ten sec sweep times.
General:
Power requirements: ±10% of 100 V, 120 V, 220 V or 240 V; 48 to 440 Hz; 500 VA except 8644B 400 VA.
Operating temperature: 0 to 55 °C
Calibration interval: Recommended three years (MTBC).
Weight: 8644B; 30 kg (67 lbs). 8664A/8665B; 35 kg (78 lbs)
Dimensions: 177H x 426W x 601D mm (7 x 16.8 x 23.7 in.). Option 010 adds 35 mm (1.4 in.) to depth.