Agilent / HP / Keysight 86130A
86130A BitAlyzer® Error Performance Analyzer
Description
The Agilent 86130A BitAlyzer is
a complete 3.6 Gb/s error performance
analyzer. It has many features,
including advanced error
analysis, that will save you time.
In addition to the suite of standard
analysis features, described here are
two additional analysis options that
will give you greater insight.
The 86130A supports two dimensions
of error correction and three
dimensions of error interleaving
before the correction is applied.
It also supports erasure processing
where inner code failures can be
used to flag outer code erasure
thereby doubling your burst correction
ability. Statistics are also maintained
during analysis to give an
ongoing monitor of the corrector
effectiveness.
Key Points
50Mb/s to 3.0Gb/s bit error ratio (BER) with internal clock source
Up to 3.6Gb/s measurements with optional external clock
Powerful error analysis built in
Excellent waveform
Easy to learn, easy to use
Specifications
Pattern Generator:
Operating Frequency:
50 MHz to 3.6 GHz with external clock
50 MHz to 3.0 GHz with internal clock source
Internal Clock Source:
Frequency Range:50 MHz to 3.0 GHz
Frequency Accuracy:±20 ppm
Data and Data Outputs:
Format: NRZ
Polarity: Normal or Inverted
Amplitude: 0.5 to 2 V in 10 mV steps
Jitter (pk-pk): <20 ps, <12 ps typical
Transition Time (10–90%): <45 ps typical
Interface: DC-coupled 50 ohm reverse terminated, APC-3.5 connector
Clock and Clock Outputs:
Amplitude: 0.5 to 2 V in 10 mV steps
Transition Time (10–90%): <45 ps typical
Interface: DC-coupled 50ohm reverse terminated, APC-3.5 connector
Clock Input:
Frequency Range: 50 MHz to 3.6 GHz
Amplitude Range: +3 dBm to –3 dBm
Interface: SMA female 50ohm, DC coupled to 0 V
Trigger Output:
Min. pulse width: (Pattern mode) 64 bits
Output levels: High –0.2 V, Low –0.9 V
Interface: 50ohm SMA female
Error Detector:
Operating Frequency:50 MHz to 3.6 GHz.
Bits:107 to 1015 bits
Data Input:
Polarity: Normal or Inverted
Input Amplitude: 0.1 to 2 V
Threshold Range: +3 to –3 V
Threshold Resolution: 0.5 mV
Terminations: Via 50ohm to –2 V, 0 V, +1.3 V
Clock Input:
Bit Rate: 50 MHz to 3.6 GHz
Data Sampling Clock Edge: Selectable Rising or Falling
Amplitude: 0.5 to 2 V
Terminations: Via 50ohm to –2 V, 0 V, +1.3 V
Interface: DC-coupled 50ohm, APC-3.5 female
General:
Dimensions:426 W x 215 H x 527 D mm approx (16.8” W x 8.5” H x 20.7” D approx)
Weight:20 kg (44 lbs)
Environmental:
Warm-up time:30 minutes
Operating Temperature Range to specification:10 to 45°C
<
p>Electrical:
Supply Voltage Parameters:90 V–250V AC, 50–60Hz
Power Consumption:<500W