Agilent / HP / Keysight 89410A
89410A Vector Signal Analyzer with W-CDMA Capability, DC to 10 MHz
Description
The Agilent/HP 89410A Vector Signal Analyzer covers a frequency range of DC to 10MHz and offers an optional second channel.
The Agilent/HP 89410A combines frequency domain and time-domain analysis to provide the most advanced measurements of complex and time-varying signals. Simultaneous time- and frequency-domain measurements and displays improve productivity and enhance ease of use.
The 89410A uses state-of-art digitizing and signal processing technology, these analyzers offer complex signal analysis, such as digital modulation analysis and AM/FM/PM demodulation, vector spectrum analysis, and time-gated spectrum analysis.
The 89410A provides unprecedented speed and power. Complex time and spectrum measurements are made and displayed up to 60 times each second.
Deep time-capture RAM is available with flexible post-processing in time and frequency domains. A variety of display types are available, including log frequency, polar, eye and constellation diagrams.
Multiple signal processors and microprocessors display signal and circuit behavior in real time and produce fast averaged measurements with enhanced signal-to-noise ratio.
The 89410A allows the user to examine only a selected part of the waveform for burst or time-varying signals. Time-selective spectrum analysis in the 89410A allows the entire time-domain signal to be viewed and a specific portion selected for frequency-domain analysis.
The selected data is identified clearly with gate markers and all of its traditional frequency-domain parameters can then be measured.
Optional waterfall and spectrogram display formats take full advantage of the high-measurement and display-update speed. Waterfalls display up to 300 successive spectra and scroll them through the display.
The Agilent 89410A provides a flexible source for circuit stimulation, Sine waves, periodic chirps, and pseudo-random noise are available, along with user-definable arbitrary waveforms.
The second channel makes it possible to measure frequency response or perform vector network analysis, and the built-in math functions facilitate measurement calibration and correction.
Key Points
DC to 10 MHz frequency range
Optional second channel
Resolution 312.5 µHz to 3 MHz
Color CRT
Accurate two channel statistical measurements such as cross-correlation and coherence
Flexible source for circuit stimulation
Sine, periodic chirp, pseudo-random noise, and arbitrary source .
DOS/LIF floppy disk
HP-IB Interface
Specifications
Frequency Range: DC - 10MHz
Amplitude Accuracy: 1Mohm
Amplitude Range (50 ohms): -30dBm to +24dBm
Amplitude Range (75 ohms): –31.761 dBm to +22.239 dBm
Frequency span: 1 Hz to 10 MHz
Center frequency tuning resolution: 0.001 Hz
Resolution bandwidth: 312.5 mHz to 3 MHz in 1, 3, 10 sequence
Connector: BNC
Input channels: 1 (second 10 MHz input channel optional)
Operating Temperature: 0° to 45°C
Storage Temperature: -20° to 60°C
Power requirements: 115 VAC operation 90 to 140 Vrms, 47 to 440 Hz; 230 VAC operation 198 to 264 Vrms, 47 to 63 Hz
Maximum power dissipation: 750 VA
Weight: 21 kg (46 lb)