Agilent / HP / Keysight 8561E
8561E Portable Spectrum Analyzer, 30 Hz to 6.5 GHz
- 90 Day Warranty Included
- 12 Month Warranty Available
- Save 80% - 90% from New
- Calibration Available
- Questions? Call 888-505-8378
Description
The Agilent 8561E portable RF spectrum analyzer offers the measurement capability and performance previously found in larger, more expensive benchtop analyzers.
This analyzer combines outstanding phase noise, sensitivity, 1 Hz resolution bandwidths, synthesized tuning and wide dynamic range in a MIL-rugged package built to withstand harsh environmental conditions.
It offers a complete solution for adjacent-channel power (ACP) testing of burst carrier signals using digital modulation, and the ability to measure occupied bandwidth percentage.
Key Points
Continuous 30 Hz to 6.5GHz sweep
Fast digital resolution bandwidths of 1, 3, 10, 30 and 100 Hz
Adjacent channel power, channel power, carrier power, occupied bandwidth percentage and time-gated measurements standard
Precision timebase and 1 Hz counter resolution
MIL-T-28800 rugged
Measurement personalities for digital radio and phase noise measurements
Specifications
Frequency range:
Internal mixing:30 Hz to 6.5 GHz
External mixing:18 GHz to 325 GHz
Sweep time:
Range:
Span = 0 Hz:50 µs to 6000 s
Span ±100 Hz:
RBW >=300 Hz: 50 ms to 2000 s
RBW <=100 Hz: 50 ms to 100 ks
Resolution bandwidth:
Range (–3 dB) :1 Hz to 1 MHz in a 1, 3, 10 sequence and 2 MHz (3 MHz at –6 dB)
Video bandwidth: 1 Hz to 3 MHz in a 1, 3, 10 sequence
Maximum safe input level:
Average continuous power: +30 dBm (1 W, input attn =10 dB)
Peak pulse power(=10 µs pulse width,<1% duty cycle):+50 dBm (100 W,input attn =30 dB)
Displayed average noise level (DANL)(0 dB attenuation, 1 Hz resolution bandwidth):
30 Hz:<=90 dBm
1 kHz:<=105 dBm
10 kHz:<=120 dBm
100 kHz:<=120 dBm
1 MHz to 10 MHz:<=140 dBm
10 MHz to 2.9 GHz:<=145 dBm
2.9 GHz to 6.46 GHz:<=145 dBm
Dynamic range:
Compression to noise:
10 MHz to 2.9 GHz:>140 dB
2.9 GHz to 6.46 GHz: >142 dB
Harmonic:
20 MHz to 1.45 GHz:>88.5 dB
1.45 GHz to 2 GHz: >98.5 dB
2 GHz to 3.25 GHz : >119 dB
Intermodulation:
10 MHz to 2.9 GHz:>103 dB
2.9 GHz to 6.46 GHz:>107 dB
Reference level range ;Log, adjustable in 0.1 dB steps:
30 Hz to 31.15 GHz: –120 to +30 dBm
31.15 GHz to 50 GHz :–115 to +30 dBm
Environmental specifications:
Calibration interval:1 year
Warm-up time: 5-minutes in ambient conditions
Temperature:–10 °C to +55 °C (operating); –51 °C to +71 °C (not operating
Maximum power dissipation:180 W
Dimensions (w/o handle, cover): 337 mm W x 187 mm H x 461 mm D
Weight (nominal):20 kg (44 lbs)
Power requirements:
115 VAC operation: 90 to 140 V rms, 3.2 A rms max, 47 to 440 Hz
230 VAC operation: 180 to 250 V rms, 1.8 A rms max, 47 to 66 Hz