Agilent / HP / Keysight 5371A
5371A Frequency and Time Interval Analyzer
Description
This unit is a general-purpose modulation domain analyzer that captures frequency or time intervals at extremely high speeds.
It combines a choice of over 60 arming and triggering configurations with built-in analysis including math, statistics, and limit testing.
It uses a continuous measurement time sampling technique to quickly capture and display data.
By eliminating reset time, measurement throughput is dramatically increased to more than 10 million measurements per second with a frequency range of up to 500MHz.
Key Points
Calculated Allan Variance specifies frequency stability in the time domain
Broad selection of measurements
Quick and easy-to-use push button analysis
Graphic display and histograms add visual meaning to numbers
Excellent single-shot 10-digit resolution at 150ps rms
Fast HP-IB throughput with up to 20,000 measurements per second
Calculated Allan Variance
Many applications specify frequency stability by Allan Variance. Allan and Root Allan Variances are calculated and displayed directly, along with traditional statistical parameters. Frequency to 500MHz is measured with zero dead time, assuring no lost information in the Allan Variance calculation.
Broad selection
Measurements include frequency and period; time interval, +/- time interval, and continuous time interval; positive or negative pulse width; rise or fall time; duty cycle; totalize; phase; and peak amplitude.
Quick and easy
Built-in statistics and analysis mean that you do not have to send data to a computer or write analysis software.
Specifications
Calculated Allan Variance specifies frequency stability in the time domain
Broad selection of measurements
Quick and easy-to-use push button analysis
Graphic display and histograms add visual meaning to numbers
Excellent single-shot 10-digit resolution at 150ps rms
Fast HP-IB throughput with up to 20,000 measurements per second
Calculated Allan Variance
Many applications specify frequency stability by Allan Variance. Allan and Root Allan Variances are calculated and displayed directly, along with traditional statistical parameters. Frequency to 500MHz is measured with zero dead time, assuring no lost information in the Allan Variance calculation.
Broad selection
Measurements include frequency and period; time interval, +/- time interval, and continuous time interval; positive or negative pulse width; rise or fall time; duty cycle; totalize; phase; and peak amplitude.
Quick and easy
Built-in statistics and analysis mean that you do not have to send data to a computer or write analysis software.