Advantest U3751
Spectrum Analyzer 9kHz to 8GHz
Description
The U3751 8 GHz Portable Spectrum Analyzer equally suitable for use on wireless communication device production lines and for field uses such as electromagnetic environment testing. The main unit weighs 5.6 kgs. or less and is designed to save space. The U3751 is twice as fast as its predecessor and is equipped with features such as LAN, designed specifically for the production line. Digitization of the IF section has enabled level measurements with outstanding reproducibility.
With a three-way power supply that includes battery operation,
better level accuracy, and a warm-up time of five minutes, this analyzer is easy to use in the field.
The U3751 includes basic spectrum analyzer measurement functions and options such as an internal tracking generator. All of these features combine to make the U3571 a portable spectrum analyzer for both factory and field use.
Key Points
RMS wave detector for essential power measurements
Compact and light-weight:
308(W)x175(H)x209(D)mm
5.6kg or less
Improved through-put:
2x processing speed of previous model
Best-in-class overall level accuracy:
0.8dB(10MHz-3GHz)
1.0dB(3GHz-8GHz)
Specifications
Frequency:
frequency range:9 kHz to 8 GHz
Pre-Amp: 10 MHz to 8 GHz
Resolution: 1 Hz to 1 kHz
Spectrum purity: -85 dBc/Hz (offset 10 kHz, span < 200 kHz)
Video bandwidth range: 10 Hz to 3 MHz (1 to 3 steps)
Frequency span Range:
5 kHz to Full, zero span
1 kHz to Full, zero span (with the OPT.70 installed)
Frequency band:
9 kHz to 3.1 GHz (band 0),
3 GHz to 8 GHz (band 1)
Resolution bandwidth
Range:
100 Hz to 3 MHz (1 to 3 steps)
30 Hz to 3 MHz (with the OPT.70 installed)
Amplitude range:
Display range: 100/50/20/10/5 dB, linear
Reference level setting range:
-140 to +40 dBm
-31.2 to 148.8 dBµV (with the OPT.15 installed)
Maximum safe input level: Attenuator = 10 dB:
Pre-Amp OFF: +30 dBm, 134 dBµV (with the OPT.15 installed)
Pre-Amp ON: +13 dBm, 120 dBµV (with the OPT.15 installed)
Amplitude accuracy:
Frequency: 20 MHz
Level: -20 dBm (75 ohm, with the OPT.15 installed)
Accuracy: ±0.3 dB, ±0.4 dB (with the OPT.15 installed)
Dynamic range:
Displayed average noise level: Reference level < -45 dBm (63.8 dBµV, with the OPT.15 installed) Resolution bandwidth 100 Hz
Pre-Amp OFF:
-123 dBm + 2f (GHz) dB (f = 3.1 GHz, band 0)
-122 dBm + 1f (GHz) dB (f = 3 GHz, band 1)
Pre-Amp ON:
-138 dBm + 3f (GHz) dB (f = 3.1 GHz, band 0)
-139 dBm + 1.3f (GHz) dB (f = 3 GHz, band 1)
General specifications:
Mass:5.6 kg or less (without option)
External dimensions(W x H x D):
Approx. 308 x 175 x 209 mm(not including protruding parts)
Approx. 337 x 190 x 307 mm(including the handle and feet)
Operating environment range:
Ambient temperature: 0 to + 50°C
Humidity: RH 85% or less (no condensation)
AC power input: Automatic switching to 100 VAC or 200 VAC
100 V: 100 to 120 V, 50/60 Hz
200 V: 220 to 240 V, 50/60 Hz
DC power input: DC + 11 V to +17 V
Power consumption:
100 VA or less (AC operation)
70 W or less (DC operation)