ICN50 InstaCal® Calibration Module

50 OHM, 2 MHz to 4.0 GHz, N (m) Calibration module for the Anritsu Sitemaster Series S113C, S114C, S331C, S331D, S332C, S332D, and MT8212A.

InstaCal Calibration ModuleThe InstaCal calibration module is available for all one-port Site Master models (S113C, S114C, S331C and S332C). With InstaCal, users can cut the time required to calibrate the Site Master by as much as 50%. Moreover, InstaCal reduces the potential for calibration error. With discrete calibration components users are required to connect, disconnect, and reconnect the various calibration components during the calibration process, which greatly increases the potential for calibration/measurement error. With InstaCal, users are only required to connect the InstaCal calibration module once – the calibration process sequences automatically, ensuring an accurate calibration of the Site Master. The benefit is calibrated measurements in much less time.

Ordering and More Details:

Price: $429
Condition: These InstaCal Modules are new, and in original packaging. While supplies last!

To Order:

PDF:SiteMeter Series and ICN50 InstaCal Calibration Module Data Sheet

For SITE MASTER S100C/S200C/S300C/S800C Series:

SITE MASTER S100C/S200C/S300C/S800C Series

Specifications:

Frequency range 3.3 to 10.5 GHZ (S810C)
3.3 to 20 GHz (S820C)
Frequency accuracy (CW mode) ≤ ± 50 ppm
Frequency resolution 100 kHz
Display data points Selectable: 130, 259, 517
Immunity to interfering RF signals up to –10 dBm
Return loss Range: 0 to 54 dB, Resolution: 0.01 dB
SWR Range: 1 to 65, Resolution: 0.01
Cable/Waveguide Loss Range: 0 to 54 dB, Resolution: 0.01 dB
Distance-to-fault
  • Vertical range :
    • Return loss: 0 to 54 dB
    • SWR: 1 to 65
  • Horizontal range: (# of data points –1) x resolution, where data points = 130, 259 or 517
  • Horizontal resolution, rectangular windowing resolution (meter):
  • Coax: (1.5 x 108)(υp)/Δ frequency
  • Waveguide: (1.5 x 108)(√(1–(Fc/F1)2)/Δ frequency)
RF power monitor (Option 5)
  • Display range: –80 to +80 dBm, 10 pW to 100 kW
  • Detector range: –45 to +20 dBm, 10 μW to 100 mW
  • Offset range: 0 to +60 dB
  • Resolution: 0.1 dB, 0.1 x W
Trace memory 200
Instrument configuration with calibration 10
Markers 6 for all models
Maximum input without damage N(f) test port: +22 dBm
RF power detector: +20 dBm, 50 Ω
Temperature Operating: 0°C to 50°C
Storage: –20°C to 75°C
Weight 2.14 kg (4.76 lbs.) nominal
Size 25.4 cm x 17.8 cm x 6.1 cm (10 in x 7 in x 2.4 in)